OPT-AP1024F Voltage analog controller
Catalog Download Demo & SDK |
Model No. |
Model | Channel | Light |
OPT-AP1024F-1 | 1 | for 10mA - 1A 24 V lights |
OPT-AP1024F-2 | 2 | for 10mA - 1A 24 V lights |
OPT-AP1024F-3 | 3 | for 10mA - 1A 24 V lights |
OPT-AP1024F-4 | 4 | for 10mA - 1A 24 V lights |
Product Features 1. Manual stepless intensity control. 2. Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of the illumination device. Width of the trigger pulse can be defined. 3. Easy to install: screw and DIN rail mounting available |
Device Overview |
No. | Item | Description |
1 | Intensity adjustment | One key per channel |
2 | TS Trigger switch key | To switch between "ON" and "OFF" trigger mode |
3 | AC power input | Input voltage 100 - 240 V AC, 50/60 Hz |
4 | Ground | Ground protection |
5 | Trigger connector | For connection with an external trigger source such as a PLC, sensor or camera |
6 | Light connector | For 24 V lights, < 1A |
7 | Power | To turn the controller on/off |
Remark: The drawing below is only valid for AP1024F-4 which with 4 light connectors. And light connector numbers of AP1024F-1/2/3 are 1, 2, or 3 respectively. |
Connection Setup Step 1: Turn the intensity adjustment wheels to zero (counterclockwise). Step 2: Connect the light with the controller; pls. refer to the drawing above. Step 3: For external triggering, connect the external trigger source with the trigger port. Step 4: Connect the controller with a 100 - 240 V AC power source and switch the controller on. The indicator is lit. Step 5: Turn the intensity adjustment key until the intended brightness of the light is reached. |
Parameter Descripition |
Items | Parameter | Description | |
Output voltage | 14.0~24.0V(±0.2V) | Continuous voltage adjustment available | |
Intensity control | stepless | Munual adjust key | |
External trigger | Synchronous strobe with external signal | ||
Trigger mode | ON / OFF | Supports NPN trigger | |
Trigger delay time | ≤80 μs | ||
External trigger frequency | 1KHz Max | ||
Trigger control | On/Off switch | Pressing the TS switch to change the mode between ON and OFF | |
Output power | 20 W per channel | Total output power of AP1024F-1/2< 30 W Total output power of AP1024F- 3/4< 40 W | |
Input Voltage | 100 - 240 V AC 50/60 Hz | ||
Standby power consumption | AP1024F-1 | <3.5W | Testing at 220 V AC |
AP1024F-2 | <3.6W | ||
AP1024F-3 | <4.5W | ||
AP1024F-4 | <5.0W | ||
Hi-Pot test | 1500 V AC, max. 1 minute | Leak current < 10 mA | |
Insulation resistance | 500 V DC | >20 MΩ | |
Working temp. | -5°C - 50°C | ||
Size(mm) | 73.5*129.5*166 | ||
Weight [kg] | AP1024F-1/2 | 0.6±0.02 | |
AP1024F-3/4 | 0.7±0.02 |
Trigger Port and Setup AP1024F-1/2/3/4 offer 1, 2, 3, or 4 channels respectively, each channel has a “+” and “-“ input port. See the drawing of the trigger port of AP1024F-4 below. Please refer to the connection scheme for details. |
TS | Trigger mode | Description |
Up | ON | Tirg+ and Trig- port is disconnected, the light is on; Trig+ and Trig- port is connected, the light is off. |
Down | OFF | Tirg+ and Trig- port is disconnected, the light is off; Trig+ and Trig- port is connected, the light is on. |
Sequence Diagram ◆ ON mode When the COM port connect the external trigger signal, the lighting is on when the "trigger+" and "trigger-" port disconnected (high level trigger), the lighting is off when the "trigger+“ and "trigger -" port connected (low level trigger). |
◆ OFF mode When the COM port connect the external trigger signal, the lighting is off when the "trigger+" and "trigger-" port disconnected (high level trigger), the lighting is on when the "trigger+“ and "trigger -" disconnected (low level trigger). |
Wiring Scheme of Switch and Trigger Port |
Dimensions [mm] |