OPT-DPH20048-4 Strobe digital controller


Download

Manual:

OPT-DPH20048-4  manual.zip

Drawing:

OPT-DPH20048-4.PDF

DEMO & SDK

DEMO & SDK.zip

Model No.

Product Features

1. RS232 communication

2. For strobing LED illuminations with higher brightness; the width of the output pulses can be set from 1 to 1023 µs

3. Multiple channels can be controlled simultaneously.

4. Internal self-trigger function, self-trigger cycle adjustable from 15 to 1000 ms.

5.Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of  the illumination device.

6. Easy to install: screw and DIN rail mounting available .

Device Overview

NO.

        Item

Description

1

5-digit display

The first number indicates the channel and the other 4 numbers show trigger pulse

width or self-trigger cycle

2

Internal / external trigger switch

EXT TRIG: External trigger; INT TRIG: Internal trigger

3

Serial port, female

To connect with PC via RS232

4

AC power input

100 - 240 V AC, 50/60 Hz

5

Intensity adjustment

To adjust width of the trigger pulse or self trigger cycle

6

Light connector

In total, four lights can be controlled individually 

7

Trigger connector

For connection with an external trigger source such as a PLC,  sensor or camera

8

Power

To turn the controller on/off

Connection Setup

Step 1: Refer to drawing above on how to connect the light with the controller.

Step 2: For external trigger, connect the external trigger source with the trigger port.

Step 3: Connect the controller with an 100 - 240 V AC power source and switch the controller on. 

            The digital display is lit. If the intensity of the light shall be controlled via PC, you need to 

            connect the PC with an RS232 cable or Ethernet cable before the controller is switched on. 

            Use the provided software or your own application to communicate with the controller. 

            You can adjust the settings via the PC or manually.

Parameter Descripition

Item

Parameter

Description

Input voltage

100-240 V AC

50/60Hz

Output voltage

48 V


External trigger

Level trigger


Trigger pulse width

1 - 1023 μs

Controlled by intensity adjustment key or via PC,

each channel can be adjusted with a different value

Internal trigger

Yes

Switch "Internal / external trigger switch" to "INT TRIG", 

and external trigger will be disabled

Internal trigger 

pulse width

15 – 1000 ms

Controlled by intensity adjustment key or via PC,

each channel can be adjusted with a different value

Short circuit protection

Yes

Protection shuts down the related channel and “ER2” appears on the display

Over current 

protection

Yes

When the current is over 10% of set value the related channel is shut down                  and “ER1” appears on the display

Peak current

20A/CH


Communication

RS232


Standby power 

consumption

≤ 3.4W


Hi-Pot test

1500 V AC, max. 1 minunte

Leak current < 10 mA

Insulation resistance

500 V DC

Insulation resistance >20 MΩ

Working temperature

-5°C - 50°C


Size [mm]

91 x 132.41 x 171 mm


Weight [kg]

1.1 kg



Trigger Port and Setup

Switch the "Internal / external trigger switch" to "EXT TRIG"; 

The trigger pulse width can be set from 1~1023μs.

The trigger mode of this type controller is level trigger, so the trigger mode can be achieved by rising edge trigger and falling edge trigger.

There are 4 trigger channels: 4 connectors for Trigger +, and "COM" is the common interface of Trigger -.

The high voltage level (input voltage range is 5V to 24V) and low voltage level (input voltage range is 0V-2V) are separated by the dual optocoupler inside.

The default trigger mode is rising edge trigger, but it can be adjusted to falling edge trigger by the trigger switch key on the panel.


Sequence Diagram

Falling edge
Rising edge

Instruction:

T1 is the trigger delay time while T2 is the width of the trigger pulse.

T1≤80 μs; T2 can be set from 1 to 1023 μs

Wiring Diagram of Two Use Cases

     Trigger Source                                   Light Controller

      Trigger Source                                       Light Controller

Trigger Input Circuit for NPN Type Trigger
Trigger Input Circuit for PNP Type Trigger

Dimensions [mm]

Model Table
Series Model Output (Blue/Green/White) Output (Red) Color 2D Drawing Controller